New Hampshire Bids > Bid Detail

Chiller Preventative Maintenance & Vibration and Oil Analyses

Agency:
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159548705503140
Posted Date: Dec 1, 2023
Due Date: Dec 16, 2023
Source: https://sam.gov/opp/572e63dbdc...
Follow
Chiller Preventative Maintenance & Vibration and Oil Analyses
Active
Contract Opportunity
Notice ID
W913E524Q0001
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
USACE
Sub Command
OTHER DIVISION
Office
W2R2 COLD RGNS RSCH ENG LAB
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Original Published Date: Nov 30, 2023 06:00 pm CST
  • Original Date Offers Due: Dec 16, 2023 12:00 pm CST
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Dec 31, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Hanover , NH 03755
    USA
Description

This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.



The solicitation number W913E524Q0001 is being issued as a request for quotation (RFQ).



The associated North American Industry Classification System (NAICS) code is 238220 – Plumbing, Heating, and Air Conditioning Contractors which has a size standard of $19M. This requirement is a Total Small Business Set-Aside in accordance with FAR 19.502-2.



The U.S. Army Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, New Hampshire requires a Contractor to conduct preventative maintenance on one (1) 23-ton ammonia chiller system (hereafter referred to as the 23-ton #1 system), and vibration and oil analyses on two (2) industrial medium-temperature chillers (hereafter referred to as MTC#1 and MTC#2) and one (1) low-temperature chiller (LTC).



Requirement: The Contractor shall furnish all labor, supervision, tools, materials, equipment, incidental engineering, transportation, and any other items and services necessary to perform the tasks under the 8,000-hour service interval on the 23-ton #1 system and perform the vibration and oil analyses on MTC#1, MTC#2, and LTC. All work on the 23-ton #1 system, MTC#1, MTC#2, and LTC will follow guidance in each system’s respective manual and guidance from manufacturers regarding safety, materials used, and methods.




  • 23-Ton #1 System: The Contractor shall perform all maintenance tasks recommended under an 8,000-hour service interval as shown in attachment A, Table 5-1. The Contractor will provide a written report documenting all maintenance performed, the status of each component prior to maintenance, any measurements taken, along with any additional noteworthy findings.




  • MTC#1, MTC#2, and LTC: The Contractor shall perform vibration and oil analyses utilizing similar methods as the previous analyses. Previous vibration and oil analyses are presented in attachment B for reference to what is expected. The Contractor must use a method of data collection and analysis that documents at least the same data as, and can be directly compared to, the previous analyses.




  • The Contractor shall have a minimum of five years’ experience in installation, troubleshooting and maintenance of GEA-manufactured chillers. The Contractor must also have the experience and permissions to utilize GEA’s vibration monitoring and analysis platform.



Please reference the attached RFQ for instructions and applicable provisions and clauses.



Award will be made to the responsible offeror whose offer represents the Best Value to the Government, in consideration of all factors. The basis for award will be an acceptable offer, the price of which may not be the lowest. The Government’s determination of what represents the best value for this requirement shall be based on the Government’s confidence that the services being quoted meet the following: 1) technical capability to provide the requested services and as outlined in Section C, Performance Work

Statement (PWS), to include the proprietary vibration analyses using GEA software and the necessary tools in accordance with GEA requirements, 2) the contractor’s emphasize expertise on refrigeration systems applications of these compressor systems, 3) total quoted price, 4) proposed delivery schedule, and 5) demonstration of experience of a minimum of five (5) years of experience maintaining GEA manufactured chillers, similar to the 23-ton #1, MTC#1, MTC#2, and LTC systems.



FOB Destination: CRREL, 72 Lyme Road, Hanover, New Hampshire 03755-1290.



Payment Terms: Net 30



Please provide responses to this notice, no later than Thursday, 14 December 2023, 12:00 PM, Central Time (CT) to:



Kim.D.Roberson@usace.army.mil



Telephone responses will not be accepted.



*Note: To be eligible for award of a Government contract, vendors must be actively registered in the System for Award Management (SAM), have no active exclusions, and complete representations and certifications. For more information, review the SAM website at https://www.sam.gov.


Attachments/Links
Contact Information
Contracting Office Address
  • KO CONTRACTING OFFICE VCCO 72 LYME ROAD
  • HANOVER , NH 03755-1290
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Nov 30, 2023 06:00 pm CSTCombined Synopsis/Solicitation (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.